How to determine the correct size system for your boat.
-
Determine the volume (length x width x height) of the engine compartment to be protected.
-
FG Series Systems are lighter Aluminum cylinders that are not refillable.
-
FD Series Systems are steel cylinders that are refillable in the event of a discharge. We strongly recommend that all diesel engined boats should fit an automatic engine shutdown system to avoid the system agent being dispersed.
Specifications:
- Unit Size (3.1" Diameter x 12" Height) System comes with Automatic heat activation. Manual Discharge cables are available and sold separately as an option, just as engine shutdowns, and audible alarms, on this page.
Certifications:
- U.S.C.G. Approved
- FM Approved
Featuring FM 200 CLEAN AGENT Extinguishing Agent
- Clean Agent (Leaves no residue)
- Fore use in normally unoccupied areas only (i.e.boat engine compartments)
- U.S. EPA Accepted Halon Alternative
Sea-Fire offers many models available for compartment protection from 25cubic feet up to 1500 cubic feet. All systems are pre-engineered, and filled with FM 200 clean fire suppression agent. Cylinders mount directly into the engine compartment, or modular cabinet. Systems are activated automatically by heat, or by an optional manual pull cable.
- Utilizes FM-200 agent
- For gasoline and diesel powered craft
- Tested performance to -40°F
- Light-weight compact corrosion resistant aluminum cylinders and valves for easy fit and installation
- 100% leak-tested
- Available in automatic or auto/manual configurations
- Non-refillable
- United States Coast Guard Approved
- Three year manufacturer warranty