Fire-Lite Alarms- Addressable FACP, Releasing Control Panel 1-2 SLC (Up to 318 pts/SLC, 24VDC)
FEATURES
80-character LCD with backlighting
One Signaling Line Circuit (expandable to two) meets NFPA Style 4, 6, or 7 requirements
318 Addressable Devices, 159 Detectors and 159 Control, Relay, or Monitor Modules per SLC
Auto-program (learn mode) reduces installation time
Two Style Y/Z (Class B/A) Notification Appliance Circuits (NACs)
Selectable NAC Synchronization Protocol (System Sensor, Gentex, or Wheelock)
Optional DACT/Modem with Remote Upload/Download Capability
UL listed, CSFM, MEA, and FM Approved
SPECIFICATIONS |
AC Power: |
120VAC, 60 HZ, 3.2 amps, 14AWG Minimum Wire Size |
Battery: |
Type: Sealed Lead Acid Only (7-25 Amp Hour) Charging Circuit: 27.6VDC at 1.0 amps
|
SLC: |
Voltage: 24VDC Nominal, 27.6VDC Maximum Current: 100mA Normal,400mA Short Circuit Loop Resistance: 40 Ohms Length: 10,000' (Twisted, Shielded Pair) 3000' (Untwisted, Unshielded Pair)
|
NAC: |
Voltage: 24VDC Nominal Current: 3.0 Amps End Of Line Resistor: 4.7K Ohms, 1/2 Watt
|
Relays: |
Programmable: Two, 2.0 Amps at 30VDC, 0.5 Amps at 30VAC, Form-C Trouble: 2.0 Amps at 30VDC, 0.5 Amps at 30VAC, Form-C
|
Auxiliary Outputs: |
Resettable Power: 24VDC Nominal, 3.0 Amps Maximum Nonresettable Power: Two, 24VDC Nominal, 3.0 Amps Maximum
|
Dimensions: |
Height: 18 1/2 " Width: 15 1/2 " Depth: 4 3/8 "
|
|
Price: $1,864.95
Buy Product Online | Visit Store Home
|
Other Items from Fire Alarm Control Panels
Fire-Lite Alarms- FACP, 2-Zone, Style B, 24VDC, 1 Style Y NAC - FireLite's® Micro-Scan Series of CONVENTIONAL FIRE ALARM CONTROL PANELS (FACPs) are easy to install, program and operate. The MS2F and MS4F bring the latest in microprocessor technology to conventional fire controls. They are compatible with the new i3 Series smoke detectors from System Sensor®, which provide such advanced features as drift compensation, maintenance alert and freeze warning. Automatic synchronization of audio/visual devices is provided using the System Sensor, Wheelock or Gentex protocol. These synchronization protocols include the ability to use a single pair of wires to silence audible devices while strobes continue to flash. The MS2F and MS4F are also compatible with conventional input devices such as 2- and 4-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally open contact devices.
Fire-Lite Alarms- FACP, 4-Zone, Style B/D, 24VDC, 2 Style Y/Z NAC - FireLite's® Micro-Scan Series of CONVENTIONAL FIRE ALARM CONTROL PANELS (FACPs) are easy to install, program and operate. The MS2F and MS4F bring the latest in microprocessor technology to conventional fire controls. They are compatible with the new i3 Series smoke detectors from System Sensor®, which provide such advanced features as drift compensation, maintenance alert and freeze warning. Automatic synchronization of audio/visual devices is provided using the System Sensor, Wheelock or Gentex protocol. These synchronization protocols include the ability to use a single pair of wires to silence audible devices while strobes continue to flash. The MS2F and MS4F are also compatible with conventional input devices such as 2- and 4-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally open contact devices.
Fire-Lite- Class A Converter for IDC & NAC (MS4F Only) - FireLite's® Micro-Scan Series of CONVENTIONAL FIRE ALARM CONTROL PANELS (FACPs) are easy to install, program and operate. The MS2F and MS4F bring the latest in microprocessor technology to conventional fire controls. They are compatible with the new i3 Series smoke detectors from System Sensor®, which provide such advanced features as drift compensation, maintenance alert and freeze warning. Automatic synchronization of audio/visual devices is provided using the System Sensor, Wheelock or Gentex protocol. These synchronization protocols include the ability to use a single pair of wires to silence audible devices while strobes continue to flash. The MS2F and MS4F are also compatible with conventional input devices such as 2- and 4-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally open contact devices.
Fire-Lite- Remote Station or Municipal Box Output - FireLite's® Micro-Scan Series of CONVENTIONAL FIRE ALARM CONTROL PANELS (FACPs) are easy to install, program and operate. The MS2F and MS4F bring the latest in microprocessor technology to conventional fire controls. They are compatible with the new i3 Series smoke detectors from System Sensor®, which provide such advanced features as drift compensation, maintenance alert and freeze warning. Automatic synchronization of audio/visual devices is provided using the System Sensor, Wheelock or Gentex protocol. These synchronization protocols include the ability to use a single pair of wires to silence audible devices while strobes continue to flash. The MS2F and MS4F are also compatible with conventional input devices such as 2- and 4-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally open contact devices.
Fire-Lite- Annunciator Driver (Supports DDPRZA4XF, MS4F Only) - FireLite's® Micro-Scan Series of CONVENTIONAL FIRE ALARM CONTROL PANELS (FACPs) are easy to install, program and operate. The MS2F and MS4F bring the latest in microprocessor technology to conventional fire controls. They are compatible with the new i3 Series smoke detectors from System Sensor®, which provide such advanced features as drift compensation, maintenance alert and freeze warning. Automatic synchronization of audio/visual devices is provided using the System Sensor, Wheelock or Gentex protocol. These synchronization protocols include the ability to use a single pair of wires to silence audible devices while strobes continue to flash. The MS2F and MS4F are also compatible with conventional input devices such as 2- and 4-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally open contact devices.
Fire-Lite- Annunciator, 4 Alm & 1 Tbl LED (Requires DDP4XLMF, MS4F Only) - FireLite's® Micro-Scan Series of CONVENTIONAL FIRE ALARM CONTROL PANELS (FACPs) are easy to install, program and operate. The MS2F and MS4F bring the latest in microprocessor technology to conventional fire controls. They are compatible with the new i3 Series smoke detectors from System Sensor®, which provide such advanced features as drift compensation, maintenance alert and freeze warning. Automatic synchronization of audio/visual devices is provided using the System Sensor, Wheelock or Gentex protocol. These synchronization protocols include the ability to use a single pair of wires to silence audible devices while strobes continue to flash. The MS2F and MS4F are also compatible with conventional input devices such as 2- and 4-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally open contact devices.
Fire-Lite- Relay Module, 4-Zone, Alarm & Trouble Relays (MS4F Only) - FireLite's® Micro-Scan Series of CONVENTIONAL FIRE ALARM CONTROL PANELS (FACPs) are easy to install, program and operate. The MS2F and MS4F bring the latest in microprocessor technology to conventional fire controls. They are compatible with the new i3 Series smoke detectors from System Sensor®, which provide such advanced features as drift compensation, maintenance alert and freeze warning. Automatic synchronization of audio/visual devices is provided using the System Sensor, Wheelock or Gentex protocol. These synchronization protocols include the ability to use a single pair of wires to silence audible devices while strobes continue to flash. The MS2F and MS4F are also compatible with conventional input devices such as 2- and 4-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally open contact devices.
Fire-Lite Alarms- FACP, 5-Zone, 2 NAC, 24VDC, w/ Built-In DACT - FireLite's® MS5024F is a 24V, 5-ZONE FIRE ALARM CONTROL PANEL (FACP) with built-in communicator. This integral communicator transmits event information (fire alarms, troubles, supervisory alarms, etc.) to a UL listed central station. The MS5024F may be used in a variety of cost-effective applications, including local fire alarm control panel (communicator disabled), fire alarm control panel/communicator, stand-alone sprinkler supervisory communicator or slave communicator to a UL listed host fire alarm panel (requires normally open dry contacts to trigger 5 channels). Selectable transmission formats allow the MS5024F to communicate to virtually all central stations.
Fire-Lite- Annunciator, 5 Alarm & 1 Trouble LEDs (Requires DDPADM24F) - FireLite's® MS5024F is a 24V, 5-ZONE FIRE ALARM CONTROL PANEL (FACP) with built-in communicator. This integral communicator transmits event information (fire alarms, troubles, supervisory alarms, etc.) to a UL listed central station. The MS5024F may be used in a variety of cost-effective applications, including local fire alarm control panel (communicator disabled), fire alarm control panel/communicator, stand-alone sprinkler supervisory communicator or slave communicator to a UL listed host fire alarm panel (requires normally open dry contacts to trigger 5 channels). Selectable transmission formats allow the MS5024F to communicate to virtually all central stations.
Fire-Lite- Class A Converter Module - FireLite's® MS5024F is a 24V, 5-ZONE FIRE ALARM CONTROL PANEL (FACP) with built-in communicator. This integral communicator transmits event information (fire alarms, troubles, supervisory alarms, etc.) to a UL listed central station. The MS5024F may be used in a variety of cost-effective applications, including local fire alarm control panel (communicator disabled), fire alarm control panel/communicator, stand-alone sprinkler supervisory communicator or slave communicator to a UL listed host fire alarm panel (requires normally open dry contacts to trigger 5 channels). Selectable transmission formats allow the MS5024F to communicate to virtually all central stations.
Fire-Lite Alarms-FACP, 10-Zone, Class B, 24VDC, w/ Built-In DACT/Modem - FireLite’s® MS5210UDF is a 24V, 10-ZONE FIRE ALARM CONTROL PANEL (FACP) with built-in communicator and remote site upload/download capability. The integral communicator transmits event information (fire alarms, troubles, supervisory alarms, etc.) to a UL listed central station. Selectable transmission formats allow the MS5210UDF to communicate to virtually all central stations.
|