Other Items from Power Supplies & Test Equipment
Fire-Lite- Battery Box (for Two 12 - 18AH Batteries) - FireLite’s® BB Series BATTERY BOXES are designed to house batteries that exceed the capacity of the fire alarm control cabinet. Additionally, the DDPBB26F and DDPBB55F can be used to house the DDPCHG75F battery charger.
Brooks- Battery Box (for Two 26AH Batteries) - FireLite’s® BB Series BATTERY BOXES are designed to house batteries that exceed the capacity of the fire alarm control cabinet. Additionally, the DDPBB26F and DDPBB55F can be used to house the DDPCHG75F battery charger.
Brooks- Battery Charger (for 25 – 75AH Sealed Lead Acid Batteries) - FireLite’s® DDPCHG75 BATTERY CHARGER is designed to charge lead-acid batteries that provide emergency standby power for a Fire Alarm Control Panel (FACP) and related equipment. Two 12V batteries are used in series to supply a nominal 24VDC. Able to charge batteries from 25-75AH and is compatible with any FACP that allows the disabling of the control panel battery charger.
Fire-Lite- Battery Box (for Two 26 - 60AH Batteries) - FireLite’s® BB Series BATTERY BOXES are designed to house batteries that exceed the capacity of the fire alarm control cabinet. Additionally, the DDPBB26F and DDPBB55F can be used to house the DDPCHG75F battery charger.
Compact Carry Case for Analyzer - FIRESAFETYPLUS.COM's state-of-the-art BATTERY ANALYZERS help you perform all the necessary service on any fire alarm control panel or accessory - with no guesswork!
Cellchecker Pulse Load Battery Tester - Fundamentally different to traditional battery testers, cellchecker Lead Acid Pulse Load Battery Tester provides a comprehensive test of a battery’s state of charge and condition using pulse load technology. With accurate pulse load testing, it tests the ability to deliver current and to maintain voltage under load, as well as battery performance - not just voltage or internal resistance. It identifies weak or failing batteries and the LED indicates percentage of remaining battery capacity. With a fast test time - right at 15 seconds - this tester is easy to use, is battery safe (does not damage or drain the battery) and produces accurate results on new, partially discharged and stored batteries.
Fire-Lite- Remote Power Supply/NAC Expander w/ Synch, 6A - FireLite’s® FCPS24FS6F and FCPS24FS8F are compact, cost-effective, REMOTE POWER SUPPLIES WITH BATTERY CHARGER . The FCPS24FS6F and FCPS24FS8F may be connected to any 12V or 24V Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance Circuit (NAC) expansion to support ADA requirements and NAC synchronization or auxiliary power to support 24V system accessories. These supplies provide regulated and filtered 24VDC power to 4 circuits configured as either 4 Class B (Style Y) or Class A (Style Z with NACZ4F option module) NACs. When used as an auxiliary power source, the 4 circuits may be configured as all nonresettable all resettable or 2 nonresettable and 2 resettable. They are capable of charging up to 18AH batteries. Batteries larger than 7AH must be mounted in a BB Series battery box. If the system requirements exceed 18AH, the DDPCHG75F may be used to charger batteries up to 75AH.
Fire-Lite- Remote Power Supply/NAC Expander w/ Synch, 8A - FireLite’s® FCPS24FS6F and FCPS24FS8F are compact, cost-effective, REMOTE POWER SUPPLIES WITH BATTERY CHARGER . The FCPS24FS6F and FCPS24FS8F may be connected to any 12V or 24V Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance Circuit (NAC) expansion to support ADA requirements and NAC synchronization or auxiliary power to support 24V system accessories. These supplies provide regulated and filtered 24VDC power to 4 circuits configured as either 4 Class B (Style Y) or Class A (Style Z with NACZ4F option module) NACs. When used as an auxiliary power source, the 4 circuits may be configured as all nonresettable all resettable or 2 nonresettable and 2 resettable. They are capable of charging up to 18AH batteries. Batteries larger than 7AH must be mounted in a BB Series battery box. If the system requirements exceed 18AH, the DDPCHG75F may be used to charger batteries up to 75AH.
Fire-Lite Alarms- Class A Converter (for FCPS24FS6F or FCPS24FS8F) - FireLite’s® FCPS24FS6F and FCPS24FS8F are compact, cost-effective, REMOTE POWER SUPPLIES WITH BATTERY CHARGER . The FCPS24FS6F and FCPS24FS8F may be connected to any 12V or 24V Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance Circuit (NAC) expansion to support ADA requirements and NAC synchronization or auxiliary power to support 24V system accessories. These supplies provide regulated and filtered 24VDC power to 4 circuits configured as either 4 Class B (Style Y) or Class A (Style Z with NACZ4F option module) NACs. When used as an auxiliary power source, the 4 circuits may be configured as all nonresettable all resettable or 2 nonresettable and 2 resettable. They are capable of charging up to 18AH batteries. Batteries larger than 7AH must be mounted in a BB Series battery box. If the system requirements exceed 18AH, the DDPCHG75F may be used to charger batteries up to 75AH.
59" Aerosol Extension (Use w/ DDPN30) - SMOKE ALARM TESTER is great for testing both photoelectric and ionization alarms. Non-toxic and environmentally safe, 2 1/2 oz gives 100+ bursts. For high, hard-to-reach alarms, try the DDPN30 with DDPN59. NOTE: Maximum number of extensions is 5 (34').
Canned Air 2000, 10 oz - CANNED AIR is nonflammable, nonresidual and nonabrasive with zero ozone depletion potential. Canned Air is moisture free and delivers up to 96 lbs per square inch of pressure. Great for cleaning smoke alarms, panels and office equipment. Comes with plastic delivery tube for hard-to-reach places. Net weight 10 oz.
|